FSP 150-GO102Pro

Outdoor Carrier Ethernet and IP demarcation

Public outdoor small cells, Wi-Fi and closed circuit TV (CCTV) require connectivity services which end outside a controlled environment. But service providers don’t want to invest in expensive and unsightly cabinets. That’s why small environmentally sealed network demarcation devices are a game changer.

Communication service providers (CSP) struggle to cope with a high number of specialized boxes. They need a single demarcation product that can cover a wide range of applications and be effective even under harsh environmental condi-tions. Our FSP 150-GO102Pro, a member of the market-leading FSP 150 family, makes a real difference. Its small size and low power consumption make it easy to install and simple to configure. It supports a comprehensive set of Carrier Ethernet and IP connectivity services. Automated testing and in-service monitoring protocols simplify any phase of the service lifecycle. What’s more, our FSP 150-GO102Pro also provides precise synchronization. Such a unique combination of features makes it the perfect solution for connecting small cell sites.

images not found

Your benefits

  • Universal demarcation

    Multi-layer Carrier Ethernet and IP integration for a single demarcation device.
  • Synchronizing any cell site

    Highly precise, assured distribution of time and frequency meeting LTE and emerging 5G requirements.
  • Versatile mounting and compact design

    Unobtrusive, compact and hardened design for a wide range of locations such as walls, poles and street cabinets.
  • Service life cycle management

    Comprehensive set of protocols for fast and efficient service activation, testing and monitoring.
  • Operational convenience

    Simple reset button allowing craft engineers to reinitialize the ZTP process without a need for performing local debug.
  • Open programmability

    Open programming interfaces supporting bandwidth slicing and auto-provisioned bandwidth services.

High-level specifications

images not found

Applications in your network

images not found

Ruggedized cell site demarcation device for deployment on walls, poles and street cabinet

  • Unique combination of Carrier Ethernet and IP features with synchronization capabilities
  • Optional power-over-Ethernet (PoE) power sourcing equipment (PSE) on access ports for CCTV, Wi-Fi or any connected device
  • Optional PoE powered device (PD) on access ports for powering the device from subtended equipment
  • Choice of variants to fit wide range of deployments from full outdoors to tight spaces inside street furniture
  • Integrates with ADVA optical access layer for efficient use of the fiber network; for instance using CWDM BiDi interfaces in a single-fiber working architecture

FSP 150-GO102 Series overview

images not found

Access capacity

  • Two 10/100/1000BaseT or 100/1000BaseX (SFP) port1,2
  • Two 10/100/1000BaseT ports3
  • One access port can be reassigned to be network port1,2

Network interface

  • One 100/1000BaseX (SFP) port

Synchronization

  • ITU-T G.8261 / G.8262 / G.8264 Synchronous Ethernet on all interfaces
  • Sync status message support
  • IEEE 1588v2 precision time protocol (PTP)
  • ITU-T G.8275.1 PTP Telecom Profile
  • G.8271 Annex A.1 1 PPS / TOD out

VLAN support

  • 4096 VLANs (IEEE 802.1Q customer-tagged) and stacked VLANs (Q-in-Q service provider tagged)
  • 2-tag management (push/pop/swap) for c-tag and s-tag
  • IEEE 802.1ad provider bridging (c-tag, s-tag)
  • Ethertype translation
  • Eight Ethernet virtual circuits (EVC)
  • 9612 byte-per-frame MTU transparency

Layer 2 traffic management

  • Acceptable client frame policy: tagged or untagged
  • Service classification based on IEEE 802.1p, 802.1Q and IP-TOS/DSCP
  • VLAN tag priority mapping (IEEE 802.1ad PCP encoding)
  • MEF-compliant policing (CIR/CBS/EIR/EBS) with threecolor marking and eight classes of service
  • Port shaping on transmit for both client and network ports
  • MEF 10.3 hierarchical policing
  • DiffServ supporting WFQ/SP mix

Layer 3 traffic management

  • L2-L4 Access control lists (ACL) for classification
  • VRF-lite virtual routing and forwarding supporting IPv4
  • BGP and OSPF dynamic routing
  • DHCP relay agent
  • DSCP remarking

Operation, administration and maintenance (OAM)

  • IEEE 802.3ah EFM-OAM link management
  • IEEE 802.1ag connectivity fault management (CFM) with hardware assistance
  • ITU-T Y.1731 performance monitoring
  • ITU-T Y.1564 service activation testing
  • Terminal and facility loopbacks on port- and EVC-level for all interfaces
  • Cable diagnostics with benchmarks (electrical interfaces only)
  • Embedded RFC 2544 test generator and analyzer (ECPA)
  • MEF-compliant Layer 2 control protocol disposition and extensive filter options for Layer 2 packet type
  • Link loss forwarding to signal local link and network path failures
  • Dying gasp message for power-failure alarming (EFMOAM and SNMP trap option)

Performance monitoring

  • RFC 2819 RMON Etherstats on a per-port and per-service basis
  • 15-minute and 1-day performance data bins
  • IEEE 802.3ah/ITU-T G.8021 PHY level monitoring
  • ITU-T Y.1731 single- and dual-ended frame loss measurement
  • Synthetic frame loss and delay measurement for multi-point service monitoring
  • TWAMP sender/reflectors for L3 based service assurance
  • Multi-CoS monitoring on EVCs scaling up to 32 simultaneous SOAM flows
  • Threshold-setting and threshold-crossing alerts
  • Physical parameter monitoring for SFP optics, including TCAs
  • Temperature monitoring and thermal alarms

Zero-touch provisioning

  • DHCP/BOOTP auto-configuration
  • IEEE 802.1x port authentication (supplicant and authenticator)
  • Text-based configuration files
  • TFTP/SCP for software image upgrade and configuration file copy

Management and security

Local management

  • USB connector using CLI
  • Reset button1,2

Remote management

  • In-band VLAN and MAC-based management tunnels
  • Fully interoperable with other FSP 150 products

Management protocols

  • IPv4 and IPv6 DCN protocol stacks, including dual-stack operation and 6-over-4 tunnels
  • Telnet, SSH (v1/v2), HTTP/HTTPS, SNMP (v1/v2c/v3)
  • NETCONF/YANG, OpenFlow

Secure administration

  • Configuration database backup and restore
  • System software download via FTP, HTTPS, SFTP or SCP (dual flash banks)
  • Remote authentication via RADIUS/TACACS
  • SNMPv3 with authentication and encryption
  • IPsec on management traffic
  • Access control list (ACL)

IP routing

  • DHCP, RIPv2 and static routes, ARP cache access control

System logging

  • Alarm log, audit log and security log

Regulatory and standards compliance

  • MEF CE 2.0 compliant
  • IEEE 802.1Q (VLAN), 802.1p (Priority), 802.1ag (CFM), 802.3ah (EFM), 802.1x
  • ITU-T Y.1731, G.8010/Y.1306, G.8011.1+2
  • MEF-6.1, -9, -10.3, -11, -14, -20, -21, -22.1, -23.1, -25, -26.1, -30, -33, -35, -36
  • IETF RFC 2544 (frame tests), RFC 2863 (IF-MIB), RFC 2865 (RADIUS), RFC 2819 (RMON), RFC 5357 (TWAMP)
  • MEF-compliant ITU-T Y.1564 service activation testing
  • IEEE 802.3at Type 1 Powered Device1 (DC variant only
  • IEEE 802.3at Type 2 Power Sourcing Equipment2
  • ANSI C84.1-1989

Product Legend

  • 1FSP 150-GO102Pro (S)
  • 2FSP 150-GO102Pro (SP)
  • 3FSP 150-GO102Pro (Sm)
  • ETSI 300 132-2, BTNR2511, ETS 300-019, ETS 300-019-2-[1,2,3,4], ETS 300-753
  • Telcordia GR-499 1,2, GR-63-CORE 1,2, GR-3108-CORE 1,2, SR-332 1,2
  • Safety IEC/UL/EN 60950, 21CFR1040.10, EN 60825, EN 50371, EN 300-386, EN 50160, IEC 60320/C14
  • EMI EN 300-3861,2,, EN 61000-4-53, GR-1089-CORE 1,2, ETS 300-132, FCC Part 15, Class A, Industry Canada

Environmental

  • Dimensions (W x H x D):
  • − 160mm x 240mm x 67mm / 6.3” x 9.4” x 2.6” 1,2
  • − 100mm x 145mm x 52.3mm / 3.9” x 5.7” x 2.1” 3
  • Operating temperature:
  • − FSP 150-GO102Pro (S): -40 to 70°C
  • − FSP 150-GO102Pro (SP): -40 to 65°C
  • − FSP 150-GO102Pro (Sm): -40 to 65°C
  • GR-3108-CORE Class 1, 2, 31, 4, ETSI EN300 019-1-3.1, 3.2, 3.3(**), 3.41, 3.5, 3.6, 4.1, 4.1E(***),4.2H1,
  • Storage temperature:
  • − -40 to +70°C (GR-63-CORE, ETS 300 019-1-1)
  • Humidity:
  • − 5 to 100% condensing (GR-3108-CORE Class 1, 2, 31, 4, ETSI EN300 019-1-3.1, 3.2, 3.3(**), 3.41, 3.5, 3.6, 4.1, 4.1E, 4.2H1,2)
  • Enclosure sealing: IEC 60529 IP653 / IP671,
  • Climatic, biological, chemical, mechanical substances, mechanical, EMC, electrical, fire, acoustic and earthquake conditions conform to GR-3108-CORE 6, ETSI EN300 019-1-3-5, 1-4-5
  • Integrated PSU1,2:
  • − 110/240 VAC,
  • − -48 to -72VDC
  • − PoE-powered device1, 802.3at type 1
  • External PSU3 : 110/240 VAC
  • Power consumption:
  • − Minimum: 8.0W;
  • − Nominal: 10.6W1,3 / 87.4W2;
  • – Maximum: 12.9W1,3 / 94.7W2 (including power supplied to 2xPoE devices, 30W each)
  1. (**) Excluding solar load for FSP 150-GO102Pro (Sm)
  2. (***) Minimum operating temperature restricted to -40°C